A comprehensive fire detection system for Cardo Brussels

Texte Philippe Selke Photos Live Emotions Studio

En version radio, détecteur et sirène communiquent par faisceau hertzien avec un émetteur-récepteur par étage, relié quant à lui en filaire avec la centrale incendie du bâtiment.
En version radio, détecteur et sirène communiquent par faisceau hertzien avec un émetteur-récepteur par étage, relié quant à lui en filaire avec la centrale incendie du bâtiment.

From the Louvre and Charleroi City Hall to the renovated Notre-Dame de Paris, … the French manufacturer DEF helps protect a range of heritage buildings from fire with detection systems that are both effective and discreet. In Brussels, the former Sheraton, now Cardo Brussels following an extensive renovation, also benefits from DEF’s expertise, with a comprehensive fire detection system operating largely on radio frequencies. 

Before its renovation, the hotel had a fire detection system that did not cover all areas. DEF Belgium supplied its client Sotrelco with several hundred smoke detectors and alarm sounders to install a comprehensive system compliant with the NBN S21-100 standard. Among other requirements, this standard specifies an alarm sound level of 75 decibels “at bed level”, meaning that both a detector and a sounder had to be installed in each of the 532 rooms, whereas the sounder had previously been in the corridor. The various communal areas were also equipped in accordance with the standard.

DEF Belgium supplied several hundred smoke detectors and alarm sounders to install a comprehensive system compliant with the NBN S21-100 standard.

Eric Vermeulen, International Solution Market Manager at DEF Belgium: “Given the number of devices to be installed, and to avoid damaging the finishes already in place, we used radio-frequency detectors and sounders for most of the system rather than wired units. In this type of installation, the detector and sounder communicate by radio link with a transceiver installed on each floor in a nearby technical area. The transceiver is in turn wired to the building’s fire alarm control panel. Once installed, all these devices were configured by our team. Radio systems of this kind are standardised, with compliance testing and a declaration of performance required. The available frequency bands are limited, and in a building like the Cardo hotel, where several hundred units operate side by side, an unusual situation, we had to work across the frequency bands to avoid interference between floors, for example.”  

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeRenovating existing buildings
  • SubjectConstruction
Share this article

Follow on Construire la Wallonie

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.