In the previous issue of Construire la Wallonie, we introduced the reform of school buildings launched by Minister Frédéric Daerden.

One of the challenges of this reform, among many others, is compliance with fire safety standards. This is an opportunity to take a brief look at the situation facing designers and builders.

Responsibility for fire safety in school buildings rests with the organising authorities. These operate independently in subsidised private education, and in municipal and provincial education. For education organised by the Wallonia-Brussels Federation, Wallonie-Bruxelles Enseignement (WBE) is the sole organising authority.

New boarding house at IESCF in Beloeil (2016): all fire doors are fitted with electromagnetic hold-open devices.

Standards and risk assessment

The school standard (NBN S 21-204), which provides the basis for all projects, takes account of how buildings are used (traditional, overnight, special education, etc.) and sets additional requirements on top of the
“basic standards”. However, it dates from 1982 and is therefore outdated in many respects. It has also sometimes proved imprecise, leaving it open to interpretation. Fortunately, an update has been announced. The section on fire safety in new school buildings is expected to be published shortly, while the section on existing school buildings will take longer. 

The SIPPT website is an extremely rich source of information. Its purpose is to provide first-line information.

The risk assessment that every head of an establishment or business must carry out has shifted the focus from an obligation of means (a technical standard that might, for example, specify the required Rf rating for a door in a particular case) to an obligation of result: preventing any accident. This more holistic approach is likely to allow greater architectural freedom. For example, if detection is installed throughout, it may be possible to be less demanding about the reaction to fire of construction materials. This enables a healthy, constructive discussion between designers and prevention advisers. But how far should the risk assessment go? Should it take account of how the building might change over time? A room currently used as a dining hall could become an archive room, for example. One thing is certain: to carry out their risk assessment, schools should first seek the advice of the public fire and rescue service, formerly known as the SRI. 

The exits are designed both to prevent pupils from running away, deter intruders and allow rapid evacuation in the event of a fire.

When the architect faces the fire

Architects face an ever-growing body of standards and regulations that must somehow be incorporated. Ultimately, however, the building must remain functional and appeal to its occupants. 

To achieve this, it all starts with drawing up a brief that gives a clear understanding of the occupant’s educational project and also makes clear that safety is non-negotiable. How, for example, can compartmentation be properly designed for an “open school” educational project? The atrium is a perennial favourite with architectural practices. A defining feature of the project, it is nevertheless often dropped after the first review by the SIPPT (Internal Service for Prevention and Protection at Work of the Wallonia-Brussels Federation), or even by the fire brigade. They also pay close attention to the materials selected, as some do not perform as expected in a fire. This somewhat limits the palette available to architects. 

Extension under construction (2016) for Ath Royal Athenaeum: a louvred smoke vent is installed above the stairwell.

Another source of frustration for some architects is signage, which can somewhat detract from the beauty of their work. Some therefore want to integrate it so that it is less visible, contrary to the purpose of these standardised pictograms in terms of size and colour.  

Reconciling fire safety with planning requirements, EPB requirements and other regulations is often an impossible task. Smoke vents are one example. Few are compliant, and there is not yet an EPB smoke vent. The challenge is, of course, even greater when bringing older buildings up to standard…    

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeBuilding and site safety and security
  • SubjectNews
Share this article

Follow on Construire la Wallonie

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.