Extend the service life of your concrete structure

Corrosion never lets up, particularly in steel-reinforced concrete structures, where the right method is needed to mitigate and prevent it. Corrosion can be defined as the conversion of a refined metal into more stable oxides through the consumption of oxygen and water. Concrete provides a natural shield that protects reinforcing steel from corrosion. The highly alkaline environment created by the cement matrix surrounding the reinforcing steel causes a passive layer to form around the reinforcing bar. This impermeable oxide film prevents further corrosion reactions by completely isolating the steel surface. However, this protective film is maintained only as long as the highly alkaline environment generated by the cement matrix persists. Carbonation caused by exposure to carbon dioxide dissolved in water reduces the pH of the cement matrix. Chloride ions also disrupt the passive layer and cause corrosion. When the passive layer breaks down, corrosion reactions begin and damage the reinforcing steel.
Although corrosion cannot be avoided, there are many ways to prevent it. Several types of corrosion inhibitor are available on the market. They contain chemical compounds that prevent corrosion reactions on steel reinforcement. All inhibitors must reach the concrete around the reinforcing steel to protect it. To achieve this, corrosion inhibitors can either be added to concrete admixtures and mixed directly into fresh concrete, or applied to the surface of hardened concrete (SACI, surface-applied corrosion inhibitors). The first type of inhibitor can only be used in new structures, while the second has been developed specifically for the renovation of existing structures.
MasterProtect 8500 CI: the latest in reinforcing steel protection
There is no longer any need to choose between the ideal solution for new structures and one for existing structures. MasterProtect 8500 CI by Master Builders Solution is a new corrosion inhibitor for application to both new and existing structures, and has proven effective even when cracks form after application. MasterProtect 8500 CI is a silane-based corrosion inhibitor with a dual function. Applied to the surface, it can be used as part of a corrosion prevention or inhibition strategy, as well as to protect against corrosion. MasterProtect 8500 CI is a revolutionary blend of high-grade silanes with a specific corrosion inhibitor added. The inhibitor remains latent in the concrete until activated by moisture entering through the surface as a result of cracking or concrete ageing. The inhibitor is not visible in dry conditions, as MasterProtect 8500 CI does not alter the appearance of the concrete. However, when the concrete is wet, its water repellency (the beading effect) is readily visible on the surface. In addition, MasterProtect 8500 CI has a very low viscosity, which improves penetration into concrete across a wide temperature range. It also has a lower VOC content and a higher flash point, making the product much easier and safer to handle and apply than many other inhibitors.

How does MasterProtect 8500 CI’s dual functionality work?
Traditional surface-applied corrosion inhibitors need to penetrate deep into the concrete to reach the reinforcing steel. There, the functional group acts on the surface of the reinforcing bars, repassivating the steel and reducing active and subsequent corrosion. MasterProtect 8500CI goes a step further with its dual functionality.
The first part of MasterProtect 8500 CI’s dual functionality is the hydrophobic effect produced by its blend of high-quality silanes, which prevents moisture and chlorides from entering the concrete. Depending on the chemical reaction involved, silanes can be produced with different functions. MasterProtect 8500CI uses several silane functions to create different effects on the concrete substrate, including corrosion inhibition and the formation of a hydrophobic layer that protects the concrete against liquid water ingress while remaining permeable to water vapour. It prevents further moisture from entering the concrete, while allowing any moisture already in the substrate to evaporate. This keeps the concrete consistently dry and increases its electrical resistivity. Since concrete can be considered an electrolyte for reinforcing steel, higher resistivity prevents electrochemical reactions. In addition, reinforcing steel is rapidly passivated in dry, alkaline concrete. Combined with the lack of water and the high resistivity of the concrete, this significantly reduces the corrosion rate.
The latent inhibitor is blended with the silanes, forming the second component of MasterProtect 8500 CI’s dual functionality. Latent inhibitors are essential for providing long-term corrosion protection to reinforced concrete structures. Regardless of the age and quality of the concrete, cracking can occur at any point during a structure’s service life. Concrete containing reinforcing steel is prone to cracking for several reasons. Cracking also breaches the hydrophobic shield created by the silanes in MasterProtect 8500 CI. Water and chloride ions can enter the crack and damage the reinforcing steel. At this point, the dual functionality comes into play and MasterProtect 8500 CI continues to protect the reinforcement. The latent inhibitors remain dormant in the concrete until its impermeability decreases over time or the concrete cracks. At that point, they are activated, become mobile and penetrate deeper into the concrete with the moisture. The reinforcing steel therefore remains protected.
MasterProtect 8500 CI’s dual functionality sets it apart from the many inhibitors on the market. In addition to the hydrophobic shield created by its revolutionary blend of silanes, the latent inhibitor ensures long-term protection. This effect extends the service life of all types of reinforced concrete structures, as demonstrated by various independent tests.